2700 University
City of Saint Paul
2700 University Ave. Saint Paul, MN 55114
General
Energy
Carbon
Energy Consumption
32 kBtu/sf-yr
0
Net zero
163
Average building

<b>SB 2030 Standard</b><br>65 kBtu/sf/year <b>As Designed</b><br>31.61 kBtu/sf/year
This graph shows the project’s energy use intensity (EUI), measured in kilo (1,000) British Thermal Units per square foot per year (kBtu/sf/year). It shows the project-specific SB 2030 Energy Standard (which is 60% less than a typical building), the predicted EUI from the project’s energy model, and the actual annual EUI from meter readings.
Energy Strategies
Appliances
  • All Available Appliances Energy Star Certified
Domestic Hot Water
  • 95% or greater DHW Efficiency (Natural Gas Fueled)
Envelope / Insulation
  • Glazing with SHGC Under 0.4
  • Low-Albedo Roof
  • R-20 to R-30 Wall Insulation (for Opaque Walls)
  • R-60 or Greater Roof Insulation
  • Shades or Overhangs
HVAC
  • Carbon Monoxide Garage Ventilation Control
  • Economizer
  • High Efficiency Fans
Lighting
  • LED Lighting
  • Occupancy or Vacancy Sensors
  • Provide Daylighting Through Side Windows
  • Reduced Lighting Power Density