Phillips Aquatics Center
Metropolitan Council
2323 11th Ave. S Minneapolis, MN 55404
General
Energy
Carbon
Water
Stormwater
Cost
Carbon Emissions
44 lbs/sf-yr
0
Net zero
71
Average building

Note: The graph below shows data submitted by the project team and has not undergone a third-party review.

<b>SB 2030 Standard</b><br>34 pounds CO2e/sf/year <b>As Designed</b><br>43.6 pounds CO2e/sf/year
The greenhouse gas emissions associated with the project’s annual energy use are calculated in pounds of carbon dioxide equivalents per square foot per year (lbs CO2e/sf/year). It shows the project-specific SB 2030 Carbon Standard, the predicted carbon emissions from the fuel mixture specified in the project’s energy model, and the actual annual carbon emissions calculated from meter readings (if available).
Energy Strategies
Appliances
  • All Available Appliances Energy Star Certified
Domestic Hot Water
  • 95% or greater DHW Efficiency (Natural Gas Fueled)
Envelope / Insulation
  • Glazing with SHGC Under 0.4
HVAC
  • Carbon Dioxide Occupancy Sensors
  • Economizer
  • Energy Recovery System (Including Heat Recovery)
  • High Efficiency Fans
  • Variable Speed Drives
Lighting
  • LED Lighting
  • Occupancy or Vacancy Sensors
Metering
  • Dedicated Plug Load Electric Panel
Design
  • Reuse Existing Building

<< Back to Case Studies Home