Ely Public Library

224 E Chapman Street Ely, MN 55731
General
Energy
Carbon
Water
Energy Consumption
69 kBtu/sf-yr
0
Net zero
170
Average building

Note: The graph below shows data submitted by the project team and has not undergone a third-party review.

<b>SB 2030 Standard</b><br>68 kBtu/sf/year <b>As Designed</b><br>69.03 kBtu/sf/year
This graph shows the project’s energy use intensity (EUI), measured in kilo (1,000) British Thermal Units per square foot per year (kBtu/sf/year). It shows the project-specific SB 2030 Energy Standard, the predicted EUI from the project’s energy model, and the actual annual EUI from meter readings (if available).
Energy Strategies
Domestic Hot Water
  • 95% or greater DHW Efficiency (Natural Gas Fueled)
  • Recirculating Hot Water Pump
Envelope / Insulation
  • Glazing with SHGC Under 0.4
  • R-20 to R-30 Wall Insulation (for Opaque Walls)
HVAC
  • Carbon Monoxide Garage Ventilation Control
  • Economizer
Lighting
  • Occupancy or Vacancy Sensors
Fixtures
  • Low Flow Aerators (faucets) Under 1.5 gpm
  • Low Flow Aerators (faucets) Under 2.0 gpm

<< Back to Case Studies Home

 B3 HomeB3 Home

 GuidelinesGuidelines

 SB 2030 Energy StandardSB 2030 Energy Standard

 BenchmarkingBenchmarking

 Energy Efficient OperationsEnergy Efficient Operations

 Post Occupancy EvaluationPost Occupancy Evaluation

Sponsors

Project Team

Case Studies Database

Admin Login

B3 Case Studies v4.1.0.4035